Contact us today 
Hello guest
Your basket is empty

VCI BAGS & FILM

£0.00
VCI Film (Volatile Corrosion Inhibitors) VCI products offer corrosion protection without having to be in direct contact with, or coated onto the parts that are being protected. Metal parts merely need to be enclosed in or with a VCI product (where airflow is minimized) for protection to occur. With VCI, it is no longer necessary to apply messy oils, greases and other corrosion protection compounds, and incur the cost of their removal.zerust-film PSL combine the use of vapor corrosion inhibitors with material sciences, and process management expertise to implement custom corrosion solutions for a customer or throughout an entire supply chain. FAQ How do VCI Products Prevent Corrosion VCI products prevent corrosion in several ways. 1) By acting as a protective barrier from external dirt and abrasion, and also as a barrier to help block the diffusion of corrosive acid gas pollutants, from outside the ICT® packaging material, (such as sulfur dioxide or hydrogen sulfide) – thereby preventing contact of these corrosive gases with enclosed metal surfaces. 2) By vapor corrosion inhibitors that passivate the electron flow between the anodic and cathodic areas on metal surfaces and interrupt the electro-chemical corrosion process. 3) By adding water repulsion properties to the metal surface, which inhibit water from permeating the metal surface and providing the electrolyte for corrosion reactions. The vapor corrosion inhibitor portion of VCI products is made of proprietary chemical formulations that are invisible, odorless, non-toxic, non-reactive, non-flammable and non-allergenic. These chemical formulations release a corrosion inhibiting vapor that diffuses throughout an enclosure that either contains ICT® formulations or is made from ICT® materials, and settles on exposed metal surfaces to form a microscopic corrosion inhibiting layer. This protective layer will remain on the surface of the metal as long as there is no significant, continuous exchange of air within the enclosure. Ideally, there should be less than one air exchange per day (for example, when an electrical cabinet or package is opened briefly and occasionally). Once the metal part is removed from the enclosure, the corrosion inhibiting layer is no longer kept in place by equilibrium with the ICT® source, and it dissipates from metal surfaces (typically within about an hour) leaving the metal part clean, dry and corrosion-free. VCI film is an ease-to-user packaging film that contains our proven VCI corrosion inhibiting technology. VCI Film is cost-effective and versatile protection against corrosion damage for metals, such as iron, steel or cast iron, in typical shipping and storage conditions. If you are thinking of using VCI to protect your items please call us to arrange a meeting and help guide you to the protection you require. MORE VCI FAQ’S 1. What is the difference between “shelf life” vs. “in-service life”? The shelf life is the duration of time that unused VCI products can be stored prior to use without losing their effectiveness. The in-service life is the duration of time that VCI products will protect clean metal objects from corrosion if used properly. 2. What is the shelf life of VCI Products? Most VCI products have a shelf life of up to two years when the product is stored in an external bag or box, out of direct sunlight and under shelter. 3. What is the in-service or useful life of VCI Products? Most VCI products have an in-service life of up to five years when protecting clean metal surfaces and when used as recommended by our representatives. 4. Can your VCI bags be reused? Yes, if the bags are still in good condition without holes or tears. Bags that have an excessive number of holes or tears, have large holes or tears, or have begun to crack or lose strength due to excessive exposure to direct sunlight will not provide adequate corrosion protection and should not be reused. 5. What if I have a rip in my VCI bag? What should I do? If the rip is small, you can cover the rip or hole with a high quality piece of tape that is designed to adhere to “low energy” surfaces like polyethylene. Or, you can fold over and staple the area shut and then seal over the holes made by the staples with the recommended tape. If you have a large rip that you cannot close easily with tape or staples, you should replace the bag with a new one. The best seal is always a “heat seal”. 6. Can I use my VCI bag in conjunction with oil coatings? A light oil coating on the metal part is fine to use with a VCI bag. A heavy oil coating may affect the performance of the ICT® bag by keeping the corrosion inhibiting vapor molecules from reaching the metal surface. Please contact us to determine the suitability of the oil and application. 7. How do I know which of your products to use for my type of metal? Ferrous: Iron, steel and cast iron metals are protected using the Trademark yellow VCI Ferrous Packaging. Non-Ferrous: Aluminum (and aluminum alloys containing copper and/or manganese), copper, brass, bronze and fully galvanized steel are protected using blue or clear VCI Non-Ferrous Packaging. Multimetal: Products that contain combinations of the Ferrous and Non-Ferrous metals listed above can be protected using green or clear VCI Multimetal Packaging. Silver: Is protected from tarnishing with clear VCI Silver Packaging. Although VCI products are usually sold in the above standard colors to help our customers distinguish the type of metal protection they are using, we are able to custom produce most VCI products in any color of your choice. 8. Can used VCI films be recycled? Yes. VCI films made of polyethylene and polypropylene have been recycled for years. VCI products, themselves, are produced using only virgin materials to assure a high level of quality and consistency for our customers. 9. How do I know that I am measuring length, width and height correctly? For Flat Bag, Sheet, Sleeve, and Round Bottom Bags Width is measured from edge to edge. If it is a slit seal bag, measure inside seal to inside seal or inside seal to fold. Bag length is measured from top of bag to top of bottom seal or fold. Sleeve or sheet length is measured from cut edge to cut edge. Technical Frequently Asked Questions 1. What is corrosion? Corrosion is the chemical or electrochemical reaction between a material, usually a metal, and its environment that produces a deterioration of the material and its properties. Usually corrosion is the oxidation of metals in the presence of water or water vapor, and is known as rust (iron, steel), white rust (galvanized steel), and other terms of corrosion failures such as tarnish, pitting, flaking and spalling. There are many different types of corrosion including atmospheric corrosion, corrosion in waters, corrosion in soils, corrosion in chemical environments, mechanically assisted corrosion, high-temperature corrosion, microbiologically influenced corrosion, etc. From an economic, safety and aesthetic standpoint, atmospheric corrosion is one of the most important types of corrosion. Atmospheric corrosion is enabled by atmospheric humidity and stimulated by pollutants in the atmosphere such as acid gases [sulfur dioxide (SO 2 ), hydrogen sulfide (H 2 S), and carbon dioxide (CO 2 )], nitrogen oxides (NO and NO 2 ), ozone (O 3 ), and salts (chlorides and sulfides). 2. How is corrosion prevented? There are many different ways to prevent corrosion, including modifying the atmosphere by dehumidification, nitrogen purge, evacuation, etc., and creating a barrier on the metal surface to prevent the permeation of moisture. This barrier can be formed by a liquid coating, such as oil, or via packaging products that contain VCI or Vapor Corrosion Inhibitors. Vapor Corrosion Inhibitors work by diffusing corrosion inhibiting molecules from a source (packaging film or paper for example) to metal surfaces. These molecules settle on metal surfaces and form a protective corrosion inhibiting layer that inhibits the electro-chemical reactions that cause corrosion to form. we combine the use of vapor corrosion inhibitors with material sciences and process management expertise to implement custom corrosion solutions for a customer or throughout an entire supply chain. We call this our VCI Integrated Corrosion Technologies or “ICT®”. 3. How do VCI Products Prevent Corrosion? VCI products prevent corrosion in several ways. 1) By acting as a protective barrier from external dirt and abrasion, and also as a barrier to help block the diffusion of corrosive acid gas pollutants from outside the ICT® packaging material (such as sulfur dioxide or hydrogen sulfide) – thereby preventing contact of these corrosive gases with enclosed metal surfaces. 2) By vapor corrosion inhibitors that passivate the electron flow between the anodic and cathodic areas on metal surfaces and interrupt the electro-chemical corrosion process. 3) By adding water repulsion properties to the metal surface, which inhibit water from permeating the metal surface and providing the electrolyte for corrosion reactions. The vapor corrosion inhibitor portion of VCI products is made of proprietary chemical formulations that are invisible, odorless, non-toxic, non-reactive, non-flammable and non-allergenic. These chemical formulations release a corrosion inhibiting vapor that diffuses throughout an enclosure that either contains ICT® formulations or is made from ICT® materials, and settles on exposed metal surfaces to form a microscopic corrosion inhibiting layer. This protective layer will remain on the surface of the metal as long as there is no significant, continuous exchange of air within the enclosure. Ideally, there should be less than one air exchange per day (for example, when an electrical cabinet or package is opened briefly and occasionally). Once the metal part is removed from the enclosure, the corrosion inhibiting layer is no longer kept in place by equilibrium with the ICT® source, and it dissipates from metal surfaces (typically within about an hour) leaving the metal part clean, dry and corrosion-free . The vapor diffusing properties of our corrosion inhibiting formulations offer an important advantage over conventional inhibitor coatings since the traces of these gas molecules penetrate into inaccessible crevices, gaps, and slots, reaching the surfaces of complex-shaped articles that are difficult to coat. They are adsorbed onto the surface of the metal to form a corrosion inhibiting protective layer that is just a few molecules thick. VCI products may also include acid gas absorbing chemicals in the packaging material to act as a barrier and add another dimension to the protection of the metal content. These “scavenging” chemicals react and neutralize the polluted air that may diffuse through the VCI material. Also used are various combinations of physical barrier properties that optimize the corrosion prevention and physical protection needs of our customers. These may range from plain low density polyethylene (LDPE) material to combinations of higher strength, higher tear resistance, higher resistance to sunlight or UV, static charge dissipation, and lower diffusion for moisture or acid gas molecules. VCI products offer corrosion protection without having to be in direct contact with or coated onto the parts that are being protected. Metal parts merely need to be enclosed in or with a VCI product (where airflow is minimized) for protection to occur. With VCI, it is no longer necessary to apply messy oils, greases and other corrosion protection compounds and incur the cost of their removal. 4. How does moisture in a package affect the performance of VCI packaging products? Depending on the design of the corrosion prevention solution, some VCI packaging products may be produced from low and high density polyethylene resins and to a large extent, are resistant to vapor penetration. Some atmospheric moisture will eventually find its way into a closed package. The presence of moisture in a package can be expected during shipments across areas of high humidity. When moisture permeates through the VCI plastic packaging products (flexible and rigid) the moisture is affected by the vapor corrosion inhibitors that are present in the ICT® product. The VCI product still inhibits corrosion despite a low level of moisture passing through the plastic. Corrosion problems arise when moisture is allowed to enter a package unimpeded by the VCI packaging products, e.g. through an incorrect closure or a significant hole in the package. When there is a significant hole in the package, for example, the corrosion inhibiting molecules are allowed to escape, breaking up the protective corrosion inhibiting molecular layer that had formed on the surface of the metal. An unimpeded airflow into the package must be avoided. 5. What can be anticipated when parts that are already corroded are packaged in VCI products? When parts in an already corroded condition are packaged in VCI products, the corrosion process is slowed. However, our packaging products cannot remove corrosion that has already formed. 6. What can be anticipated when wet parts are packaged in VCI products? When wet parts are packaged in VCI products, a certain amount of corrosion can be anticipated to take place. The amount of corrosion will be a function of the time it takes for the active corrosion inhibiting molecules to saturate the package enclosure, the corrosion inhibiting effectiveness of the designed ICT® system, the amount of moisture on the part, and the pH and contaminations of the water itself. 7. How long can parts be expected to remain free of corrosion after removal from a VCI package? Tests performed with electron scanning (ESCA) microscopy show that 2-4 hours after a steel test panel is removed from a VCI package, all traces of the corrosion inhibiting molecular layer are gone from the surface of the part. The period of time before one can expect corrosion to occur on a part depends on the cleanliness of the part and the environment around the part (relative humidity, presence of pollutants or wood, temperature, etc.). 8. How long does it take for the interior of a VCI package to reach its designed corrosion prevention capability? The time required for active corrosion inhibiting molecules from the ICT® product to saturate a package is a function of the volume and temperature of the package. Protection begins as soon as corrosion inhibiting molecules reach the metal surfaces, and maximum protection is achieved when the entire environment of the package is saturated with the corrosion inhibiting molecules. Saturation in typical factory environments and in typical CKD packaging applications runs from 12 to 24 hours. 9. Does VCI have any effect on electrical or electronic components? Test data show that VCI products do not adversely affect electrical and electronic components. In fact, the corrosion inhibiting molecules actually help improve the reliability of electrical and electronic components by preventing corrosion that is too small to be seen by the naked eye. It is absolutely safe to use VCI packaging products to prevent corrosion of any instruments, devices and equipment which contain electric and electronic components. 10. Are there any inhalation or contact risks with VCI products? Test data and review of corresponding scientific literature show that there are no inhalation or contact risks with VCI products. VCI products have been reviewed and cleared for use by factory, government and military personnel by the appropriate occupational health departments, including those of all major automotive manufacturers worldwide. 11. What is the best way to store VCI products before use? we recommend keeping VCI packaging products clean, out of direct sunlight and away from water while in storage. Simply keep the products in their original shipping cartons, bags or containers. If a carton is opened, cover the products with a sheet or bag of plain polyethylene to protect the products from dust and dirt. It is also recommended that VCI products be stored in moderate temperatures, typical of most indoor workplace conditions to minimize exposure to excessive temperatures and outside elements such as direct sunlight, rain or snow. Storing VCI products correctly ensures that the products will meet or exceed their estimated shelf life. 12. What is VCI and VCI Film? VCI stands for Volatile Corrosion Inhibitors. We apply VCI technology to inhibit corrosion on metal. VCI Film is packaging that generally consists of polyethylene film that has been impregnated with chemical formulations that are unique to each manufacturer. While the underlying formulations can vary significantly, the finished products all function similarly in that they release very low concentrations (typically in parts per ten-thousandth) of invisible corrosion inhibiting vapors into the surrounding air. The vapor molecules subsequently condense onto exposed metal surfaces and form a molecular corrosion shield that can protect against rust and other forms of corrosion for up to five (5) years, and even longer in some cases. When the VCI packaging is later removed, all vapor corrosion inhibiting molecules rapidly evaporate. This leaves the metal parts clean and ready for immediate use. Please contact our sales team with any related VCI product, We are here to help you.
Quantity:
 

FREE COLLECTION

is available next day from our Stonehouse site and is not subject to a minimum order value. Normal collection hours are 8.00 am - 4.30 pm Monday to Friday.

FREE DELIVERY

is available to your place of work or business address within the GL postcode area.

VEHICLE ACCESS

Due to the size of our vehicles, we are unable to offer delivery to residential addresses.
Orders below £25.00 will incur a £6.00 delivery charge.

PLEASE NOTE:

It is the responsibility of the customer to advise us of any access restrictions that could prevent delivery. Normal next day delivery is 9.00 am - 4.00 pm Monday to Friday.
Should the above not be suitable for you please call us on 01453 822 822 to discuss the possibility of alternative delivery arrangements.

IF YOU ARE A COMPANY

please contact us direct as we can offer you trading terms and supported delivered prices on all products.
Our site uses cookies. For more information, see our cookie policy. Accept cookies and close
Reject cookies Manage settings